Centurion
Model:
Category:
The Centurion REFLOW OVEN is a forced-convection SMT reflow system designed for high-throughput PCB assembly environments, offering tight, closed-loop process control. Known for its exceptional heat transfer, the Centurion can run any profile at the lowest set point possible, minimizing thermal variations and energy consumption.
Featuring an efficient heat transfer design, the Centurion maintains a low energy consumption rate. Its robust and reliable construction, supported by over 20 years of SMT experience, ensures high uptime even under the most demanding reflow conditions. The patented CATHOX™ (Catalytic Thermal Oxidizer) reduces maintenance needs through advanced flux treatment technology, further lowering the cost of ownership. Additionally, the new 'idle mode' option decreases operational costs.
With its latest design, the Centurion achieves superior thermal transfer even with a wider process chamber, drawing on the knowledge and experience gained from previous generations. This expertise in process control ensures repeatability across the oven, meeting the stringent requirements of the most demanding customers and challenging processes globally.
Key words:
Description
| Model | CT820 | CT930 | CT1040 | CT1240 |
| Total zones | 10 | 12 | 14 | 16 |
| Heating zones | 8 | 9 | 10 | 12 |
| Cool zones | 2 | 3 | 4 | 4 |
| Total heating length(mm/in) | 2840 (111.8) | 3195 (125.8) | 3550(139.8) | 4260 (167.7 ) |
| System length (AIR) | 4150 (163.4) | 4860(191.3) | 5570(219.3) | 6280 (247.2) |
| System length (N2) | 4860(191.3) | 5570 (219.3) | 6280 (247.2) | 6990(275.2) |
| System width(mm/in) | 1600 (62.9) | |||
| System height(mm/in) | 1542(60.7) | |||
| Max gas temperature setpoint | 350°C | |||
| Gas temperature control accuracy | ± 1°C | |||
| Gas thermal uniformity | ± 2°C | |||
| Max process width(mm/in) | 610(24) | |||
| Max dual lane width(mm/in) | 300(11.81) | |||
| Conveyor speed range | 25 - 200 cm/min | |||
| Conveyor speed accuracy | ± 1% | |||
| PPM level of N2 machine | <50 PPM | |||
Message